Send Message
products
PRODUCTS DETAILS
Home > Products >
30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa

MOQ: 1
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T, Western Union
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextremeshell
Model Number
OWPD650L-1
Voltage Input:
30-60VDC
Power:
700W
Working Current:
15A
Motor:
Brushless Motor
Nozzle Size:
38mm
Nozzle Shape:
Pagoda
Highlight:

30-60V tailored pumps

,

120L/Min tailored pumps

,

180Kpa electric coolant pump

Product Description

30-60V Electric Coolant Pump Rated 120L/min at Head Pressure 180Kpa for Coolant Circulation in Energy Storage and Data Center Cooling System.

Product features

Product name:BLDC Electric Water Pump

Model:OWPD650L-1

Service life: 40000hrs

IP grade: IP67

Appearance: Aluminum alloy natural color

Bracket: All-in-one

Noise: ≤65dB(A)

Weight: 2.53Kg

Tightness: At 0.4Mpa, the leakage<1ml

Flame retardant: According to GB/T 2408 standard, it meets the horizontal combustion HB level and the vertical combustion V-0 level

Mechanical strength: According to QC/T413-2015 standard, Meets Severity Rating: On Engine

Prohibited substances: Meets GBT 30512-2014

 

The scope of use

Ambient temperature: -40—85℃

Liquid temperature: -40—85℃

Liquid type: Commercial coolants can be used with water pumps, but mixing different coolants is not allowed. The mixing ratio of water and antifreeze is selected in a range of 50/50 to 40/60.

In order for the cooling system to be completely filled with media, the cooling system must be completely drained to a vacuum.

Installation: Vibration and noise requirements must be taken into account in the definition of the installation location and specific fixing elements/fasteners in the application, and the installation position must avoid water accumulation on the surface/inside the connection system.

Typical applications: Energy storage thermal management system, liquid-cooled charging cabinet, data center system

 

Basic parameters:

Rated voltage: 48VDC

Operating voltage range:30-60VDC

Current rating: 15±5% A

Rated performance: 120L/min@180Kpa

Input power: 700W±5%

Maximum flow rate: 180±5% L/min

Maximum head: 23±1 m

Speed range: 2500rpm~5500rpm

Resistance: 2.6±3%Ω

Inductance: Axis-Q 14mH Axis-D 13mH

BEMF: 24.5±3%V

Number of pole pairs: 3 pairs of poles

Insulation rating: F

Electrical strength: <1mA >500MΩ

Harness length: U V W Power cord length 300mm

Plug-in information: Amphenol:AT04-3P-RD01-NFK

 

Instructions for the use of the controller

PCBA dimensions:100mm*90mm,Height:32mm

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 0

Controller Installation Dimensions:

Heatsink size:120mm*100mm,Heatsink thickness:8mm
Overall height (including PCBA):42mm,Mounting Sockets:4mm*5mm(Use M3 screws)

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 1

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 2

I/O control port 

  1. PWM. PWM input frequency: 100-1000Hz (200Hz recommended), PWM amplitude: 10-48V, duty cycle speed regulation range description: 0%-10%: pump stop (7% is recommended to stop signal), 11%-55%: pump minimum speed operation; 56%-90%: linear speed range, 91%-100%: maximum speed operation of the pump
  2. Fault. Fault feedback signal output (current type): high level (48V) for normal operation, low level (<1V) for fault, and the typical operating current for fault feedback is 5mA
  3. GND. Signal GND
  4. VSP. Analog voltage input speed regulation(0-10V)
  5. 10V. 10V supply.

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 3


Pump installation size

The performance of the pump


Schematic diagram of test bench

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 4

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 5

 

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 6

 

products
PRODUCTS DETAILS
30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa
MOQ: 1
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T, Western Union
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextremeshell
Model Number
OWPD650L-1
Voltage Input:
30-60VDC
Power:
700W
Working Current:
15A
Motor:
Brushless Motor
Nozzle Size:
38mm
Nozzle Shape:
Pagoda
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
PE bag+carton
Delivery Time:
5-10days
Payment Terms:
L/C, T/T, Western Union
Supply Ability:
10000pcs/month
Highlight

30-60V tailored pumps

,

120L/Min tailored pumps

,

180Kpa electric coolant pump

Product Description

30-60V Electric Coolant Pump Rated 120L/min at Head Pressure 180Kpa for Coolant Circulation in Energy Storage and Data Center Cooling System.

Product features

Product name:BLDC Electric Water Pump

Model:OWPD650L-1

Service life: 40000hrs

IP grade: IP67

Appearance: Aluminum alloy natural color

Bracket: All-in-one

Noise: ≤65dB(A)

Weight: 2.53Kg

Tightness: At 0.4Mpa, the leakage<1ml

Flame retardant: According to GB/T 2408 standard, it meets the horizontal combustion HB level and the vertical combustion V-0 level

Mechanical strength: According to QC/T413-2015 standard, Meets Severity Rating: On Engine

Prohibited substances: Meets GBT 30512-2014

 

The scope of use

Ambient temperature: -40—85℃

Liquid temperature: -40—85℃

Liquid type: Commercial coolants can be used with water pumps, but mixing different coolants is not allowed. The mixing ratio of water and antifreeze is selected in a range of 50/50 to 40/60.

In order for the cooling system to be completely filled with media, the cooling system must be completely drained to a vacuum.

Installation: Vibration and noise requirements must be taken into account in the definition of the installation location and specific fixing elements/fasteners in the application, and the installation position must avoid water accumulation on the surface/inside the connection system.

Typical applications: Energy storage thermal management system, liquid-cooled charging cabinet, data center system

 

Basic parameters:

Rated voltage: 48VDC

Operating voltage range:30-60VDC

Current rating: 15±5% A

Rated performance: 120L/min@180Kpa

Input power: 700W±5%

Maximum flow rate: 180±5% L/min

Maximum head: 23±1 m

Speed range: 2500rpm~5500rpm

Resistance: 2.6±3%Ω

Inductance: Axis-Q 14mH Axis-D 13mH

BEMF: 24.5±3%V

Number of pole pairs: 3 pairs of poles

Insulation rating: F

Electrical strength: <1mA >500MΩ

Harness length: U V W Power cord length 300mm

Plug-in information: Amphenol:AT04-3P-RD01-NFK

 

Instructions for the use of the controller

PCBA dimensions:100mm*90mm,Height:32mm

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 0

Controller Installation Dimensions:

Heatsink size:120mm*100mm,Heatsink thickness:8mm
Overall height (including PCBA):42mm,Mounting Sockets:4mm*5mm(Use M3 screws)

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 1

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 2

I/O control port 

  1. PWM. PWM input frequency: 100-1000Hz (200Hz recommended), PWM amplitude: 10-48V, duty cycle speed regulation range description: 0%-10%: pump stop (7% is recommended to stop signal), 11%-55%: pump minimum speed operation; 56%-90%: linear speed range, 91%-100%: maximum speed operation of the pump
  2. Fault. Fault feedback signal output (current type): high level (48V) for normal operation, low level (<1V) for fault, and the typical operating current for fault feedback is 5mA
  3. GND. Signal GND
  4. VSP. Analog voltage input speed regulation(0-10V)
  5. 10V. 10V supply.

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 3


Pump installation size

The performance of the pump


Schematic diagram of test bench

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 4

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 5

 

30-60V Electric Coolant Tailored Pumps Rated 120L/Min At Head Pressure 180Kpa 6

 

Sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2025 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.