Send Message
products
PRODUCTS DETAILS
Home > Products >
Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid

MOQ: 5 sets
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T
Supply Capacity: 10000 sets per month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL43-300
Product Name:
OWP-BL43-300 BLDC Water Pump
Usage:
Flood System, Viscous Media And Liquid
Voltage:
18-32V
Theory:
Centrifugal Pump
Power:
130W\200W\250W
Material:
Cast Aluminium/Stainless Steel
Waterproof:
IP68
Color:
Silver
Highlight:

250W Brushless DC Water Pump

,

DC Water Pump 6000L/H

Product Description

Bextreme Shell OWP-BL43-300 Industrial BLDC Water Pump 18V-32V 250W  Capacity 6000L/H For Liquid Cooled Glycol Circulation, flood system, viscous media and liquid

 

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 0

 

 

OWP-BL43-300 SERIES brushless DC water pump

Boosting/circulation/Variable-frequency/Low-noise/centrifugal pump

 

The OWP-BL43-300 industrial water pump is a high-performance pump designed for various applications. With an input voltage range of 18-32V, it offers reliable operation in different environments. Its centrifugal pump mechanism, aided by magnetic force transmission, ensures efficient water flow and optimal performance.

 

Equipped with a high efficiency brushless DC motor, this water pump delivers optimum power while consuming less energy. It boasts several protective features such as dry running protection, reverse polarity protection, overvoltage, over current, overload, and over-temperature protection. These safeguards ensure the longevity of the pump and offer peace of mind during operation.

 

With a rated head of 6M and a rated flow of 6000 L/H, the OWP-BL43-300 water pump delivers consistent and efficient performance. Its wide range operating temperature capability makes it suitable for use in various climates. Overall, this water pump offers excellent efficiency, low power consumption, and a long service life, making it a reliable choice for automotive applications.

■Performance parameter

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 1

■Selling point

  • Centrifugal pump

  • Magnetic force transmission

  • High efficiency brushless DC motor, low power consumption, high efficiency, long service life.

  • With wide range operating temperature

  • PWM signal speed controlling(optional)

  • Diagnostic signal output(optional)

  • With constant flow controlling

  • Reverse polarity protection

  • Dry running protection

  • Over Voltage, over current protection

  • Overload, over temperature protection

 

Electrical parameter

 

Working Voltage

(VDC)

Rated power

Rated flow

(L/H)

Dimensions

(mm)

Weight

(g)

 

 

 

18V-32V(24V)

 

130W

Q=5000L/H,

H≥5m

 

 

 

195*90*145

 

 

 

1950g

 

200W

Q=6000L/H,

H≥6m

 

250W

Q=6000L/H,

H≥8m

 
Connector model and the corresponding electrical properties (as shown below):
Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 2

AMP282104-1

(matched Plug AMP282080-1)

1 2
+24V DC GND

 

■Technical description (related parts in contact with the liquid)

Pump head housing: Aluminum alloy
Impeller: PPS+GF Shield cavity: PPS+GF
Shaft sleeve: carborundum composite materials
Shaft: stainless steel(3CR14) shaft
Magnet housing: PPS plastic capsulation
Seal ring: EPDM

 

Driving device (Including motor)

 
Driving rotor: PPS plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor wire frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..
 
Bracket: Steel base
Bracket hoop: US 304 stainless steel
Waterproof based on IP68 rating (en60529)
Connector model: AMP282104-1 (matched Plug AMP282080-1)
Nozzle diameter:40mm (1.5 inch)
 

 

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 3■ Mounting instruction

 
OWP-BL43-300 series pumps are centrifugal pumps which require pre-filled,
The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on .
 
1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.
 
2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.
 
3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).
 
4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .
 
5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )
 
6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).
 
7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium .
Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 4

 

■External dimension

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 5

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 6

 

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 3■ Attentions

 
1.Working ambient temperature:-40℃--120℃, should try to avoid close to three-element catalytic, gas discharge pipe system and       engine during the installation, ensure the working environment temperature.
 

2.The installation position of the water pump should as much as possible close to the low water level , to extend the service life of the   pump.
 
3.Please use the pump far from the dusty environment, the dust is harmful to reduce the service life
 

4.Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the service life of pump
 
 

 

 



 

products
PRODUCTS DETAILS
Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid
MOQ: 5 sets
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T
Supply Capacity: 10000 sets per month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL43-300
Product Name:
OWP-BL43-300 BLDC Water Pump
Usage:
Flood System, Viscous Media And Liquid
Voltage:
18-32V
Theory:
Centrifugal Pump
Power:
130W\200W\250W
Material:
Cast Aluminium/Stainless Steel
Waterproof:
IP68
Color:
Silver
Minimum Order Quantity:
5 sets
Price:
Negotiable
Packaging Details:
PE bag+carton
Delivery Time:
5-10days
Payment Terms:
L/C, T/T
Supply Ability:
10000 sets per month
Highlight

250W Brushless DC Water Pump

,

DC Water Pump 6000L/H

Product Description

Bextreme Shell OWP-BL43-300 Industrial BLDC Water Pump 18V-32V 250W  Capacity 6000L/H For Liquid Cooled Glycol Circulation, flood system, viscous media and liquid

 

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 0

 

 

OWP-BL43-300 SERIES brushless DC water pump

Boosting/circulation/Variable-frequency/Low-noise/centrifugal pump

 

The OWP-BL43-300 industrial water pump is a high-performance pump designed for various applications. With an input voltage range of 18-32V, it offers reliable operation in different environments. Its centrifugal pump mechanism, aided by magnetic force transmission, ensures efficient water flow and optimal performance.

 

Equipped with a high efficiency brushless DC motor, this water pump delivers optimum power while consuming less energy. It boasts several protective features such as dry running protection, reverse polarity protection, overvoltage, over current, overload, and over-temperature protection. These safeguards ensure the longevity of the pump and offer peace of mind during operation.

 

With a rated head of 6M and a rated flow of 6000 L/H, the OWP-BL43-300 water pump delivers consistent and efficient performance. Its wide range operating temperature capability makes it suitable for use in various climates. Overall, this water pump offers excellent efficiency, low power consumption, and a long service life, making it a reliable choice for automotive applications.

■Performance parameter

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 1

■Selling point

  • Centrifugal pump

  • Magnetic force transmission

  • High efficiency brushless DC motor, low power consumption, high efficiency, long service life.

  • With wide range operating temperature

  • PWM signal speed controlling(optional)

  • Diagnostic signal output(optional)

  • With constant flow controlling

  • Reverse polarity protection

  • Dry running protection

  • Over Voltage, over current protection

  • Overload, over temperature protection

 

Electrical parameter

 

Working Voltage

(VDC)

Rated power

Rated flow

(L/H)

Dimensions

(mm)

Weight

(g)

 

 

 

18V-32V(24V)

 

130W

Q=5000L/H,

H≥5m

 

 

 

195*90*145

 

 

 

1950g

 

200W

Q=6000L/H,

H≥6m

 

250W

Q=6000L/H,

H≥8m

 
Connector model and the corresponding electrical properties (as shown below):
Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 2

AMP282104-1

(matched Plug AMP282080-1)

1 2
+24V DC GND

 

■Technical description (related parts in contact with the liquid)

Pump head housing: Aluminum alloy
Impeller: PPS+GF Shield cavity: PPS+GF
Shaft sleeve: carborundum composite materials
Shaft: stainless steel(3CR14) shaft
Magnet housing: PPS plastic capsulation
Seal ring: EPDM

 

Driving device (Including motor)

 
Driving rotor: PPS plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor wire frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..
 
Bracket: Steel base
Bracket hoop: US 304 stainless steel
Waterproof based on IP68 rating (en60529)
Connector model: AMP282104-1 (matched Plug AMP282080-1)
Nozzle diameter:40mm (1.5 inch)
 

 

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 3■ Mounting instruction

 
OWP-BL43-300 series pumps are centrifugal pumps which require pre-filled,
The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on .
 
1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.
 
2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.
 
3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).
 
4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .
 
5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )
 
6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).
 
7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium .
Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 4

 

■External dimension

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 5

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 6

 

Industrial BLDC Water Pump 6000L/H For Flood System, Viscous Media and Liquid 3■ Attentions

 
1.Working ambient temperature:-40℃--120℃, should try to avoid close to three-element catalytic, gas discharge pipe system and       engine during the installation, ensure the working environment temperature.
 

2.The installation position of the water pump should as much as possible close to the low water level , to extend the service life of the   pump.
 
3.Please use the pump far from the dusty environment, the dust is harmful to reduce the service life
 

4.Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the service life of pump
 
 

 

 



 

Sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2025 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.