logo
Send Message
products
PRODUCTS DETAILS
Home > Products >
DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet

MOQ: 50pcs
Price: Negotiable
Standard Packaging: suite for export
Delivery Period: as confirmed
Payment Method: L/C, T/T, Western Union,PAYPAL
Supply Capacity: 10000PCS/Month
Detail Information
Place of Origin
China
Brand Name
Bextremeshell
Model Number
OWPD650B-1
Product Name:
BLDC Electric Coolant Pump
Insulation Rating:
F
IP Grade:
IP67
Rated Voltage:
48VDC
Rated Current:
15A
Rated Power:
700W
Rated Performance:
120L/min When Head Pressure Is 180Kpa
Noise:
≤65dB(A)
Bracket:
Separated
Weight:
4.26Kg
Highlight:

DC 48V electric coolant pump

,

electric coolant pump

,

DC 48V coolant pump electric

Product Description

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid-cooled in ESS Cabinet

 

Product features

Product name:BLDC Electric Water Pump

Model:OWPD650B-1

Service life: 40000hrs

IP grade: IP67

Appearance: Stainless Steel natural color

Bracket: Separated

Noise: ≤65dB(A)

Weight: 4.26Kg

Tightness: At 0.4Mpa, the leakage<1ml

Flame retardant: According to GB/T 2408 standard, it meets the horizontal combustion HB level and the vertical combustion V-0 level

Mechanical strength: According to QC/T413-2015 standard, Meets Severity Rating: On Engine

Prohibited substances: Meets GBT 30512-2014

 

Basic parameters:

Rated voltage: 48VDC

Operating voltage range:30-60VDC

Current rating: 15±5% A

Rated performance: 120L/min@180Kpa

Input power: 700W±5%

Maximum flow rate: 180±5% L/min

Maximum head: 23±1 m

Speed range: 2500rpm~5500rpm

Resistance: 2.6±3%Ω

Inductance: Axis-Q 14mH Axis-D 13mH

BEMF: 24.5±3%V

Number of pole pairs: 3 pairs of poles

Insulation rating: F

Electrical strength: <1mA >500MΩ

Harness length: U V W Power cord length 300mm

Plug-in information: Amphenol:AT04-3P-RD01-NFK

 

The scope of use

Ambient temperature: -40—85℃

Liquid temperature: -40—85℃

Liquid type: Commercial coolants can be used with water pumps, but mixing different coolants is not allowed. The mixing ratio of water and antifreeze is selected in a range of 50/50 to 40/60.

In order for the cooling system to be completely filled with media, the cooling system must be completely drained to a vacuum.

Installation: Vibration and noise requirements must be taken into account in the definition of the installation location and specific fixing elements/fasteners in the application, and the installation position must avoid water accumulation on the surface/inside the connection system.

Typical applications: Energy storage thermal management system, liquid-cooled charging cabinet, data center system

 

Instructions for the use of the controller

PCBA dimensions:100mm*90mm,Height:32mm

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 0

Controller Installation Dimensions:

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 1

Heatsink size:120mm*100mm,Heatsink thickness:8mm


Overall height (including PCBA):42mm,Mounting Sockets:4mm*5mm(Use M3 screws)

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 2

I/O control port

  1. PWM. PWM input frequency: 100-1000Hz (200Hz recommended), PWM amplitude: 10-48V, duty cycle speed regulation range description: 0%-10%: pump stop (7% is recommended to stop signal), 11%-55%: pump minimum speed operation; 56%-90%: linear speed range, 91%-100%: maximum speed operation of the pump
  2. Fault. Fault feedback signal output (current type): high level (48V) for normal operation, low level (<1V) for fault, and the typical operating current for fault feedback is 5mA
  3. GND. Signal GND
  4. VSP. Analog voltage input speed regulation(0-10V)
  5. 10V. 10V supply.

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 3DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 4

 

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 5


Pump installation size

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 6

The performance of the pump

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 7


Schematic diagram of test bench

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 8

products
PRODUCTS DETAILS
DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet
MOQ: 50pcs
Price: Negotiable
Standard Packaging: suite for export
Delivery Period: as confirmed
Payment Method: L/C, T/T, Western Union,PAYPAL
Supply Capacity: 10000PCS/Month
Detail Information
Place of Origin
China
Brand Name
Bextremeshell
Model Number
OWPD650B-1
Product Name:
BLDC Electric Coolant Pump
Insulation Rating:
F
IP Grade:
IP67
Rated Voltage:
48VDC
Rated Current:
15A
Rated Power:
700W
Rated Performance:
120L/min When Head Pressure Is 180Kpa
Noise:
≤65dB(A)
Bracket:
Separated
Weight:
4.26Kg
Minimum Order Quantity:
50pcs
Price:
Negotiable
Packaging Details:
suite for export
Delivery Time:
as confirmed
Payment Terms:
L/C, T/T, Western Union,PAYPAL
Supply Ability:
10000PCS/Month
Highlight

DC 48V electric coolant pump

,

electric coolant pump

,

DC 48V coolant pump electric

Product Description

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid-cooled in ESS Cabinet

 

Product features

Product name:BLDC Electric Water Pump

Model:OWPD650B-1

Service life: 40000hrs

IP grade: IP67

Appearance: Stainless Steel natural color

Bracket: Separated

Noise: ≤65dB(A)

Weight: 4.26Kg

Tightness: At 0.4Mpa, the leakage<1ml

Flame retardant: According to GB/T 2408 standard, it meets the horizontal combustion HB level and the vertical combustion V-0 level

Mechanical strength: According to QC/T413-2015 standard, Meets Severity Rating: On Engine

Prohibited substances: Meets GBT 30512-2014

 

Basic parameters:

Rated voltage: 48VDC

Operating voltage range:30-60VDC

Current rating: 15±5% A

Rated performance: 120L/min@180Kpa

Input power: 700W±5%

Maximum flow rate: 180±5% L/min

Maximum head: 23±1 m

Speed range: 2500rpm~5500rpm

Resistance: 2.6±3%Ω

Inductance: Axis-Q 14mH Axis-D 13mH

BEMF: 24.5±3%V

Number of pole pairs: 3 pairs of poles

Insulation rating: F

Electrical strength: <1mA >500MΩ

Harness length: U V W Power cord length 300mm

Plug-in information: Amphenol:AT04-3P-RD01-NFK

 

The scope of use

Ambient temperature: -40—85℃

Liquid temperature: -40—85℃

Liquid type: Commercial coolants can be used with water pumps, but mixing different coolants is not allowed. The mixing ratio of water and antifreeze is selected in a range of 50/50 to 40/60.

In order for the cooling system to be completely filled with media, the cooling system must be completely drained to a vacuum.

Installation: Vibration and noise requirements must be taken into account in the definition of the installation location and specific fixing elements/fasteners in the application, and the installation position must avoid water accumulation on the surface/inside the connection system.

Typical applications: Energy storage thermal management system, liquid-cooled charging cabinet, data center system

 

Instructions for the use of the controller

PCBA dimensions:100mm*90mm,Height:32mm

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 0

Controller Installation Dimensions:

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 1

Heatsink size:120mm*100mm,Heatsink thickness:8mm


Overall height (including PCBA):42mm,Mounting Sockets:4mm*5mm(Use M3 screws)

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 2

I/O control port

  1. PWM. PWM input frequency: 100-1000Hz (200Hz recommended), PWM amplitude: 10-48V, duty cycle speed regulation range description: 0%-10%: pump stop (7% is recommended to stop signal), 11%-55%: pump minimum speed operation; 56%-90%: linear speed range, 91%-100%: maximum speed operation of the pump
  2. Fault. Fault feedback signal output (current type): high level (48V) for normal operation, low level (<1V) for fault, and the typical operating current for fault feedback is 5mA
  3. GND. Signal GND
  4. VSP. Analog voltage input speed regulation(0-10V)
  5. 10V. 10V supply.

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 3DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 4

 

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 5


Pump installation size

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 6

The performance of the pump

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 7


Schematic diagram of test bench

DC 48V Input Stainless Steel Electric Coolant Pump For Liquid Cooled In ESS Cabinet 8

Sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2025 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.